Thursday 20 April 2017

smartctl en SAMSUNG HD204UI

{{

Power_On_Hours
 
Power_Cycle_Count
8339
Horas
 
1945
Count
             347,5
Dias
 
 
 
 
 
 
972,5
2 al día -> días
               4,29
Horas / ciclo
 
                  2,7
años
 
 
 
 
 
 
 
 
1945
1 al día -> días
 
 
 
                  5,3
años

 
----------------- {{
Los discos del sistema

root@sysresccd /root % fdisk -l
Disk /dev/loop0: 337.6 MiB, 353955840 bytes, 691320 sectors
Units: sectors of 1 * 512 = 512 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 512 bytes / 512 bytes


Disk /dev/sda: 1.8 TiB, 2000398934016 bytes, 3907029168 sectors
Units: sectors of 1 * 512 = 512 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 512 bytes / 512 bytes
Disklabel type: dos
Disk identifier: 0x5631ac68

Device     Boot     Start        End    Sectors  Size Id Type
/dev/sda1  *         2048     206847     204800  100M  7 HPFS/NTFS/exFAT
/dev/sda2          206848  209922040  209715193  100G  7 HPFS/NTFS/exFAT
/dev/sda3       209922048 3907025071 3697103024  1.7T  7 HPFS/NTFS/exFAT


Disk /dev/sdb: 1.8 TiB, 2000398934016 bytes, 3907029168 sectors
Units: sectors of 1 * 512 = 512 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 512 bytes / 512 bytes


Disk /dev/sdc: 984 MiB, 1031798784 bytes, 2015232 sectors
Units: sectors of 1 * 512 = 512 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 512 bytes / 512 bytes
Disklabel type: dos
Disk identifier: 0x13b0c437

Device     Boot Start     End Sectors  Size Id Type
/dev/sdc1  *     2048 2015231 2013184  983M  c W95 FAT32 (LBA)
root@sysresccd /root %

sda - es el disco original bueno.
sdb - es el recien comprodo y tuvo un error con vida 8288 horas ahora 8339

}} ----------------- {{

Versión de linux:

root@sysresccd /root % dmesg | head -1
[    0.000000] Linux version 3.18.25-std471-amd64 (root@gl-sysrcd-p11.dupoux.int) (gcc version 4.8.5 ( Gentoo 4.8.5 p1.3, pie-0.6.2) ) #2 SMP Fri Jan 1 21:48:48 UTC 2016
root@sysresccd /root % cat /proc/version
Linux version 3.18.25-std471-amd64 (root@gl-sysrcd-p11.dupoux.int) (gcc version 4.8.5 (Gentoo 4.8.5 p1.3, pie-0.6.2) ) #2 SMP Fri Jan 1 21:48:48 UTC 2016
root@sysresccd /root % cat /etc/issue
cat: /etc/issue: No such file or directory
root@sysresccd /root %


}} ----------------- {{

Prueba de escritura y lectura del disco .. copio uno entero y lo leo.


root@sysresccd /root % echo kk > kk.txt
root@sysresccd /root % cat kk.txt
kk
root@sysresccd /root % ddrescue -f /dev/sda  /dev/sdb  ddr_mapfile


GNU ddrescue 1.18.1
Press Ctrl-C to interrupt
rescued:     2000 GB,  errsize:       0 B,  current rate:   11821 kB/s
   ipos:     2000 GB,   errors:       0 ,    average rate:   91126 kB/s
   opos:     2000 GB, run time:    6.09 h ,  successful read:       0 s ago
Finished
root@sysresccd /root % ddrescue -f   /dev/sdb /dev/null ddr_mapfile2


GNU ddrescue 1.18.1
Press Ctrl-C to interrupt
rescued:     2000 GB,  errsize:       0 B,  current rate:   50487 kB/s
   ipos:     2000 GB,   errors:       0,    average rate:     108 MB/s
   opos:     2000 GB, run time:    5.14 h ,  successful read:       0 s ago
Finished
root@sysresccd /root %


}} ----------------- {{


Nota
sda - es el disco original bueno.
sdb - es el recien comprodo y tuvo un error con vida 8288 horas ahora 8339
 El error fue Error: ABRT at LBA = 0x0000000f = 15


root@sysresccd /root %
root@sysresccd /root % smartctl -a /dev/sda
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-3.18.25-std471-amd64] (local build)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     SAMSUNG SpinPoint F4 EG (AF)
Device Model:     SAMSUNG HD204UI
Serial Number:    S2HFJ1AZA08140
LU WWN Device Id: 5 0024e9 004386004
Firmware Version: 1AQ10001
User Capacity:    2,000,398,934,016 bytes [2.00 TB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    5400 rpm
Form Factor:      3.5 inches
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 6
SATA Version is:  SATA 2.6, 3.0 Gb/s
Local Time is:    Thu Apr 20 22:16:13 2017 UTC

==> WARNING: Using smartmontools or hdparm with this
drive may result in data loss due to a firmware bug.
****** THIS DRIVE MAY OR MAY NOT BE AFFECTED! ******
Buggy and fixed firmware report same version number!
See the following web pages for details:
http://knowledge.seagate.com/articles/en_US/FAQ/223571en
http://www.smartmontools.org/wiki/SamsungF4EGBadBlocks

SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
     was never started.
     Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
     without error or no self-test has ever
     been run.
Total time to complete Offline
data collection:   (21120) seconds.
Offline data collection
capabilities:     (0x5b) SMART execute Offline immediate.
     Auto Offline data collection on/off support.
     Suspend Offline collection upon new
     command.
     Offline surface scan supported.
     Self-test supported.
     No Conveyance Self-test supported.
     Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
     power-saving mode.
     Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
     General Purpose Logging supported.
Short self-test routine
recommended polling time:   (   2) minutes.
Extended self-test routine
recommended polling time:   ( 352) minutes.
SCT capabilities:         (0x003f) SCT Status supported.
     SCT Error Recovery Control supported.
     SCT Feature Control supported.
     SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   100   100   051    Pre-fail  Always       -       20848
  2 Throughput_Performance  0x0026   252   252   000    Old_age   Always       -       0
  3 Spin_Up_Time            0x0023   085   022   025    Pre-fail  Always   In_the_past 4608
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       -       416
  5 Reallocated_Sector_Ct   0x0033   252   252   010    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x002e   252   252   051    Old_age   Always       -       0
  8 Seek_Time_Performance   0x0024   252   252   015    Old_age   Offline      -       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       -       16590
 10 Spin_Retry_Count        0x0032   252   252   051    Old_age   Always       -       0
 11 Calibration_Retry_Count 0x0032   252   252   000    Old_age   Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       438
181 Program_Fail_Cnt_Total  0x0022   100   100   000    Old_age   Always       -       14823686
191 G-Sense_Error_Rate      0x0022   100   100   000    Old_age   Always       -       19
192 Power-Off_Retract_Count 0x0022   252   252   000    Old_age   Always       -       0
194 Temperature_Celsius     0x0002   064   050   000    Old_age   Always       -       35 (Min/Max 10/50)
195 Hardware_ECC_Recovered  0x003a   100   100   000    Old_age   Always       -       0
196 Reallocated_Event_Count 0x0032   252   252   000    Old_age   Always       -       0
197 Current_Pending_Sector  0x0032   099   094   000    Old_age   Always       -       152
198 Offline_Uncorrectable   0x0030   252   252   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0036   200   200   000    Old_age   Always       -       0
200 Multi_Zone_Error_Rate   0x002a   100   100   000    Old_age   Always       -       1
223 Load_Retry_Count        0x0032   252   252   000    Old_age   Always       -       0
225 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       -       443

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%     16318         -

SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Completed [00% left] (0-65535)
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root % smartctl -a /dev/sdb
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-3.18.25-std471-amd64] (local build)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     SAMSUNG SpinPoint F4 EG (AF)
Device Model:     SAMSUNG HD204UI
Serial Number:    S2H7J1CZ917597
LU WWN Device Id: 5 0024e9 00417b426
Firmware Version: 1AQ10001
User Capacity:    2,000,398,934,016 bytes [2.00 TB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    5400 rpm
Form Factor:      3.5 inches
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 6
SATA Version is:  SATA 2.6, 3.0 Gb/s
Local Time is:    Thu Apr 20 22:16:39 2017 UTC

==> WARNING: Using smartmontools or hdparm with this
drive may result in data loss due to a firmware bug.
****** THIS DRIVE MAY OR MAY NOT BE AFFECTED! ******
Buggy and fixed firmware report same version number!
See the following web pages for details:
http://knowledge.seagate.com/articles/en_US/FAQ/223571en
http://www.smartmontools.org/wiki/SamsungF4EGBadBlocks

SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
     was never started.
     Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
     without error or no self-test has ever
     been run.
Total time to complete Offline
data collection:   (20340) seconds.
Offline data collection
capabilities:     (0x5b) SMART execute Offline immediate.
     Auto Offline data collection on/off support.
     Suspend Offline collection upon new
     command.
     Offline surface scan supported.
     Self-test supported.
     No Conveyance Self-test supported.
     Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
     power-saving mode.
     Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
     General Purpose Logging supported.
Short self-test routine
recommended polling time:   (   2) minutes.
Extended self-test routine
recommended polling time:   ( 339) minutes.
SCT capabilities:         (0x003f) SCT Status supported.
     SCT Error Recovery Control supported.
     SCT Feature Control supported.
     SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   100   100   051    Pre-fail  Always       -       0
  2 Throughput_Performance  0x0026   252   252   000    Old_age   Always       -       0
  3 Spin_Up_Time            0x0023   074   067   025    Pre-fail  Always       -       8129
  4 Start_Stop_Count        0x0032   099   099   000    Old_age   Always       -       1703
  5 Reallocated_Sector_Ct   0x0033   252   252   010    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x002e   252   252   051    Old_age   Always       -       0
  8 Seek_Time_Performance   0x0024   252   252   015    Old_age   Offline      -       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       -       8339
 10 Spin_Retry_Count        0x0032   252   252   051    Old_age   Always       -       0
 11 Calibration_Retry_Count 0x0032   100   100   000    Old_age   Always       -       1
 12 Power_Cycle_Count       0x0032   099   099   000    Old_age   Always       -       1945
181 Program_Fail_Cnt_Total  0x0022   100   100   000    Old_age   Always       -       10364821
191 G-Sense_Error_Rate      0x0022   100   100   000    Old_age   Always       -       908
192 Power-Off_Retract_Count 0x0022   252   252   000    Old_age   Always       -       0
194 Temperature_Celsius     0x0002   064   056   000    Old_age   Always       -       35 (Min/Max 16/44)
195 Hardware_ECC_Recovered  0x003a   100   100   000    Old_age   Always       -       0
196 Reallocated_Event_Count 0x0032   252   252   000    Old_age   Always       -       0
197 Current_Pending_Sector  0x0032   252   252   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0030   252   252   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0036   100   100   000    Old_age   Always       -       1
200 Multi_Zone_Error_Rate   0x002a   100   100   000    Old_age   Always       -       5
223 Load_Retry_Count        0x0032   100   100   000    Old_age   Always       -       1
225 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       -       1999

SMART Error Log Version: 1
ATA Error Count: 1
 CR = Command Register [HEX]
 FR = Features Register [HEX]
 SC = Sector Count Register [HEX]
 SN = Sector Number Register [HEX]
 CL = Cylinder Low Register [HEX]
 CH = Cylinder High Register [HEX]
 DH = Device/Head Register [HEX]
 DC = Device Command Register [HEX]
 ER = Error register [HEX]
 ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 1 occurred at disk power-on lifetime: 8288 hours (345 days + 8 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 30 0f 00 00 e0  Error: ABRT at LBA = 0x0000000f = 15

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c5 ff 3f 00 00 00 e0 00      00:00:00.050  WRITE MULTIPLE
  c8 ff 01 00 00 00 e0 00      00:00:00.042  READ DMA
  c8 ff 01 00 00 00 e0 00      00:00:00.042  READ DMA
  c8 ff 01 00 00 00 e0 00      00:00:00.042  READ DMA
  f5 00 00 05 00 00 e0 00      00:00:00.041  SECURITY FREEZE LOCK

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%      8312         -
# 2  Short offline       Completed without error       00%      8293         -

SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Completed [00% left] (0-65535)
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root %


}} ----------------- {{


root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root % hdparm -i /dev/sda

/dev/sda:

 Model=SAMSUNG HD204UI, FwRev=1AQ10001, SerialNo=S2HFJ1AZA08140
 Config={ Fixed }
 RawCHS=16383/16/63, TrkSize=0, SectSize=0, ECCbytes=4
 BuffType=unknown, BuffSize=unknown, MaxMultSect=16, MultSect=off
 CurCHS=16383/16/63, CurSects=16514064, LBA=yes, LBAsects=3907029168
 IORDY=on/off, tPIO={min:120,w/IORDY:120}, tDMA={min:120,rec:120}
 PIO modes:  pio0 pio1 pio2 pio3 pio4
 DMA modes:  mdma0 mdma1 mdma2
 UDMA modes: udma0 udma1 udma2 udma3 udma4 udma5 *udma6
 AdvancedPM=yes: disabled (255) WriteCache=enabled
 Drive conforms to: unknown:  ATA/ATAPI-0,1,2,3,4,5,6,7

 * signifies the current active mode

root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root % hdparm -i /dev/sdb

/dev/sdb:

 Model=SAMSUNG HD204UI, FwRev=1AQ10001, SerialNo=S2H7J1CZ917597
 Config={ Fixed }
 RawCHS=16383/16/63, TrkSize=0, SectSize=0, ECCbytes=4
 BuffType=unknown, BuffSize=unknown, MaxMultSect=16, MultSect=off
 CurCHS=16383/16/63, CurSects=16514064, LBA=yes, LBAsects=3907029168
 IORDY=on/off, tPIO={min:120,w/IORDY:120}, tDMA={min:120,rec:120}
 PIO modes:  pio0 pio1 pio2 pio3 pio4
 DMA modes:  mdma0 mdma1 mdma2
 UDMA modes: udma0 udma1 udma2 udma3 udma4 udma5 *udma6
 AdvancedPM=yes: disabled (255) WriteCache=enabled
 Drive conforms to: unknown:  ATA/ATAPI-0,1,2,3,4,5,6,7

 * signifies the current active mode

root@sysresccd /root %
root@sysresccd /root %


}} ----------------- {{


smartctl -t short -a /dev/sdb
y luego cuando pasó el tiempo:

smartctl  -a /dev/sdb


root@sysresccd /root % smartctl  -a /dev/sdb
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-3.18.25-std471-amd64] (local build)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     SAMSUNG SpinPoint F4 EG (AF)
Device Model:     SAMSUNG HD204UI
Serial Number:    S2H7J1CZ917597
LU WWN Device Id: 5 0024e9 00417b426
Firmware Version: 1AQ10001
User Capacity:    2,000,398,934,016 bytes [2.00 TB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    5400 rpm
Form Factor:      3.5 inches
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 6
SATA Version is:  SATA 2.6, 3.0 Gb/s
Local Time is:    Thu Apr 20 23:24:58 2017 UTC

==> WARNING: Using smartmontools or hdparm with this
drive may result in data loss due to a firmware bug.
****** THIS DRIVE MAY OR MAY NOT BE AFFECTED! ******
Buggy and fixed firmware report same version number!
See the following web pages for details:
http://knowledge.seagate.com/articles/en_US/FAQ/223571en
http://www.smartmontools.org/wiki/SamsungF4EGBadBlocks

SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
     was never started.
     Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
     without error or no self-test has ever
     been run.
Total time to complete Offline
data collection:   (20340) seconds.
Offline data collection
capabilities:     (0x5b) SMART execute Offline immediate.
     Auto Offline data collection on/off support.
     Suspend Offline collection upon new
     command.
     Offline surface scan supported.
     Self-test supported.
     No Conveyance Self-test supported.
     Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
     power-saving mode.
     Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
     General Purpose Logging supported.
Short self-test routine
recommended polling time:   (   2) minutes.
Extended self-test routine
recommended polling time:   ( 339) minutes.
SCT capabilities:         (0x003f) SCT Status supported.
     SCT Error Recovery Control supported.
     SCT Feature Control supported.
     SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   100   100   051    Pre-fail  Always       -       0
  2 Throughput_Performance  0x0026   252   252   000    Old_age   Always       -       0
  3 Spin_Up_Time            0x0023   074   067   025    Pre-fail  Always       -       8129
  4 Start_Stop_Count        0x0032   099   099   000    Old_age   Always       -       1703
  5 Reallocated_Sector_Ct   0x0033   252   252   010    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x002e   252   252   051    Old_age   Always       -       0
  8 Seek_Time_Performance   0x0024   252   252   015    Old_age   Offline      -       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       -       8340
 10 Spin_Retry_Count        0x0032   252   252   051    Old_age   Always       -       0
 11 Calibration_Retry_Count 0x0032   100   100   000    Old_age   Always       -       1
 12 Power_Cycle_Count       0x0032   099   099   000    Old_age   Always       -       1945
181 Program_Fail_Cnt_Total  0x0022   100   100   000    Old_age   Always       -       10364821
191 G-Sense_Error_Rate      0x0022   100   100   000    Old_age   Always       -       908
192 Power-Off_Retract_Count 0x0022   252   252   000    Old_age   Always       -       0
194 Temperature_Celsius     0x0002   064   056   000    Old_age   Always       -       35 (Min/Max 16/44)
195 Hardware_ECC_Recovered  0x003a   100   100   000    Old_age   Always       -       0
196 Reallocated_Event_Count 0x0032   252   252   000    Old_age   Always       -       0
197 Current_Pending_Sector  0x0032   252   252   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0030   252   252   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0036   100   100   000    Old_age   Always       -       1
200 Multi_Zone_Error_Rate   0x002a   100   100   000    Old_age   Always       -       5
223 Load_Retry_Count        0x0032   100   100   000    Old_age   Always       -       1
225 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       -       1999

SMART Error Log Version: 1
ATA Error Count: 1
 CR = Command Register [HEX]
 FR = Features Register [HEX]
 SC = Sector Count Register [HEX]
 SN = Sector Number Register [HEX]
 CL = Cylinder Low Register [HEX]
 CH = Cylinder High Register [HEX]
 DH = Device/Head Register [HEX]
 DC = Device Command Register [HEX]
 ER = Error register [HEX]
 ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 1 occurred at disk power-on lifetime: 8288 hours (345 days + 8 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 30 0f 00 00 e0  Error: ABRT at LBA = 0x0000000f = 15

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c5 ff 3f 00 00 00 e0 00      00:00:00.050  WRITE MULTIPLE
  c8 ff 01 00 00 00 e0 00      00:00:00.042  READ DMA
  c8 ff 01 00 00 00 e0 00      00:00:00.042  READ DMA
  c8 ff 01 00 00 00 e0 00      00:00:00.042  READ DMA
  f5 00 00 05 00 00 e0 00      00:00:00.041  SECURITY FREEZE LOCK

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%      8340         -
# 2  Short offline       Completed without error       00%      8312         -
# 3  Short offline       Completed without error       00%      8293         -

SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Completed [00% left] (0-65535)
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

root@sysresccd /root %


root@sysresccd /root % smartctl -t short -a /dev/sda
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-3.18.25-std471-amd64] (local build)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     SAMSUNG SpinPoint F4 EG (AF)
Device Model:     SAMSUNG HD204UI
Serial Number:    S2HFJ1AZA08140
LU WWN Device Id: 5 0024e9 004386004
Firmware Version: 1AQ10001
User Capacity:    2,000,398,934,016 bytes [2.00 TB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    5400 rpm
Form Factor:      3.5 inches
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 6
SATA Version is:  SATA 2.6, 3.0 Gb/s
Local Time is:    Thu Apr 20 23:28:03 2017 UTC

==> WARNING: Using smartmontools or hdparm with this
drive may result in data loss due to a firmware bug.
****** THIS DRIVE MAY OR MAY NOT BE AFFECTED! ******
Buggy and fixed firmware report same version number!
See the following web pages for details:
http://knowledge.seagate.com/articles/en_US/FAQ/223571en
http://www.smartmontools.org/wiki/SamsungF4EGBadBlocks

SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
     was never started.
     Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
     without error or no self-test has ever
     been run.
Total time to complete Offline
data collection:   (21120) seconds.
Offline data collection
capabilities:     (0x5b) SMART execute Offline immediate.
     Auto Offline data collection on/off support.
     Suspend Offline collection upon new
     command.
     Offline surface scan supported.
     Self-test supported.
     No Conveyance Self-test supported.
     Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
     power-saving mode.
     Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
     General Purpose Logging supported.
Short self-test routine
recommended polling time:   (   2) minutes.
Extended self-test routine
recommended polling time:   ( 352) minutes.
SCT capabilities:         (0x003f) SCT Status supported.
     SCT Error Recovery Control supported.
     SCT Feature Control supported.
     SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   100   100   051    Pre-fail  Always       -       20848
  2 Throughput_Performance  0x0026   252   252   000    Old_age   Always       -       0
  3 Spin_Up_Time            0x0023   085   022   025    Pre-fail  Always   In_the_past 4608
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       -       416
  5 Reallocated_Sector_Ct   0x0033   252   252   010    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x002e   252   252   051    Old_age   Always       -       0
  8 Seek_Time_Performance   0x0024   252   252   015    Old_age   Offline      -       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       -       16591
 10 Spin_Retry_Count        0x0032   252   252   051    Old_age   Always       -       0
 11 Calibration_Retry_Count 0x0032   252   252   000    Old_age   Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       438
181 Program_Fail_Cnt_Total  0x0022   100   100   000    Old_age   Always       -       14823686
191 G-Sense_Error_Rate      0x0022   100   100   000    Old_age   Always       -       19
192 Power-Off_Retract_Count 0x0022   252   252   000    Old_age   Always       -       0
194 Temperature_Celsius     0x0002   064   050   000    Old_age   Always       -       36 (Min/Max 10/50)
195 Hardware_ECC_Recovered  0x003a   100   100   000    Old_age   Always       -       0
196 Reallocated_Event_Count 0x0032   252   252   000    Old_age   Always       -       0
197 Current_Pending_Sector  0x0032   099   094   000    Old_age   Always       -       152
198 Offline_Uncorrectable   0x0030   252   252   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0036   200   200   000    Old_age   Always       -       0
200 Multi_Zone_Error_Rate   0x002a   100   100   000    Old_age   Always       -       1
223 Load_Retry_Count        0x0032   252   252   000    Old_age   Always       -       0
225 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       -       443

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%     16318         -

SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Completed [00% left] (0-65535)
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

=== START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
Sending command: "Execute SMART Short self-test routine immediately in off-line mode".
Drive command "Execute SMART Short self-test routine immediately in off-line mode" successful.
Testing has begun.
Please wait 2 minutes for test to complete.
Test will complete after Thu Apr 20 23:30:04 2017

Use smartctl -X to abort test.
root@sysresccd /root %


root@sysresccd /root % smartctl  -a /dev/sda
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-3.18.25-std471-amd64] (local build)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     SAMSUNG SpinPoint F4 EG (AF)
Device Model:     SAMSUNG HD204UI
Serial Number:    S2HFJ1AZA08140
LU WWN Device Id: 5 0024e9 004386004
Firmware Version: 1AQ10001
User Capacity:    2,000,398,934,016 bytes [2.00 TB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    5400 rpm
Form Factor:      3.5 inches
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 6
SATA Version is:  SATA 2.6, 3.0 Gb/s
Local Time is:    Thu Apr 20 23:29:34 2017 UTC

==> WARNING: Using smartmontools or hdparm with this
drive may result in data loss due to a firmware bug.
****** THIS DRIVE MAY OR MAY NOT BE AFFECTED! ******
Buggy and fixed firmware report same version number!
See the following web pages for details:
http://knowledge.seagate.com/articles/en_US/FAQ/223571en
http://www.smartmontools.org/wiki/SamsungF4EGBadBlocks

SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
     was never started.
     Auto Offline Data Collection: Disabled.
Self-test execution status:      ( 243) Self-test routine in progress...
     30% of test remaining.
Total time to complete Offline
data collection:   (21120) seconds.
Offline data collection
capabilities:     (0x5b) SMART execute Offline immediate.
     Auto Offline data collection on/off support.
     Suspend Offline collection upon new
     command.
     Offline surface scan supported.
     Self-test supported.
     No Conveyance Self-test supported.
     Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
     power-saving mode.
     Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
     General Purpose Logging supported.
Short self-test routine
recommended polling time:   (   2) minutes.
Extended self-test routine
recommended polling time:   ( 352) minutes.
SCT capabilities:         (0x003f) SCT Status supported.
     SCT Error Recovery Control supported.
     SCT Feature Control supported.
     SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   100   100   051    Pre-fail  Always       -       20848
  2 Throughput_Performance  0x0026   252   252   000    Old_age   Always       -       0
  3 Spin_Up_Time            0x0023   085   022   025    Pre-fail  Always   In_the_past 4608
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       -       416
  5 Reallocated_Sector_Ct   0x0033   252   252   010    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x002e   252   252   051    Old_age   Always       -       0
  8 Seek_Time_Performance   0x0024   252   252   015    Old_age   Offline      -       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       -       16591
 10 Spin_Retry_Count        0x0032   252   252   051    Old_age   Always       -       0
 11 Calibration_Retry_Count 0x0032   252   252   000    Old_age   Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       438
181 Program_Fail_Cnt_Total  0x0022   100   100   000    Old_age   Always       -       14823686
191 G-Sense_Error_Rate      0x0022   100   100   000    Old_age   Always       -       19
192 Power-Off_Retract_Count 0x0022   252   252   000    Old_age   Always       -       0
194 Temperature_Celsius     0x0002   064   050   000    Old_age   Always       -       36 (Min/Max 10/50)
195 Hardware_ECC_Recovered  0x003a   100   100   000    Old_age   Always       -       0
196 Reallocated_Event_Count 0x0032   252   252   000    Old_age   Always       -       0
197 Current_Pending_Sector  0x0032   099   094   000    Old_age   Always       -       152
198 Offline_Uncorrectable   0x0030   252   252   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0036   200   200   000    Old_age   Always       -       0
200 Multi_Zone_Error_Rate   0x002a   100   100   000    Old_age   Always       -       1
223 Load_Retry_Count        0x0032   252   252   000    Old_age   Always       -       0
225 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       -       443

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%     16318         -

SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Self_test_in_progress [30% left] (0-65535)
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

root@sysresccd /root %


}} ----------------- {{


Lanzo los tests en los primero sectores .. no hay ningún error !!!


root@sysresccd /root %
root@sysresccd /root % smartctl -t select,0-999 /dev/sda
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-3.18.25-std471-amd64] (local build)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
Sending command: "Execute SMART Selective self-test routine immediately in off-line mode".
SPAN         STARTING_LBA           ENDING_LBA
   0                    0                  999
Drive command "Execute SMART Selective self-test routine immediately in off-line mode" successful.
Testing has begun.
root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root % smartctl -t select,0-999 /dev/sdb
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-3.18.25-std471-amd64] (local build)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
Sending command: "Execute SMART Selective self-test routine immediately in off-line mode".
SPAN         STARTING_LBA           ENDING_LBA
   0                    0                  999
Drive command "Execute SMART Selective self-test routine immediately in off-line mode" successful.
Testing has begun.
root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root % smartctl  -a /dev/sda
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-3.18.25-std471-amd64] (local build)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     SAMSUNG SpinPoint F4 EG (AF)
Device Model:     SAMSUNG HD204UI
Serial Number:    S2HFJ1AZA08140
LU WWN Device Id: 5 0024e9 004386004
Firmware Version: 1AQ10001
User Capacity:    2,000,398,934,016 bytes [2.00 TB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    5400 rpm
Form Factor:      3.5 inches
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 6
SATA Version is:  SATA 2.6, 3.0 Gb/s
Local Time is:    Thu Apr 20 23:35:33 2017 UTC

==> WARNING: Using smartmontools or hdparm with this
drive may result in data loss due to a firmware bug.
****** THIS DRIVE MAY OR MAY NOT BE AFFECTED! ******
Buggy and fixed firmware report same version number!
See the following web pages for details:
http://knowledge.seagate.com/articles/en_US/FAQ/223571en
http://www.smartmontools.org/wiki/SamsungF4EGBadBlocks

SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
     was never started.
     Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
     without error or no self-test has ever
     been run.
Total time to complete Offline
data collection:   (21120) seconds.
Offline data collection
capabilities:     (0x5b) SMART execute Offline immediate.
     Auto Offline data collection on/off support.
     Suspend Offline collection upon new
     command.
     Offline surface scan supported.
     Self-test supported.
     No Conveyance Self-test supported.
     Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
     power-saving mode.
     Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
     General Purpose Logging supported.
Short self-test routine
recommended polling time:   (   2) minutes.
Extended self-test routine
recommended polling time:   ( 352) minutes.
SCT capabilities:         (0x003f) SCT Status supported.
     SCT Error Recovery Control supported.
     SCT Feature Control supported.
     SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   100   100   051    Pre-fail  Always       -       20848
  2 Throughput_Performance  0x0026   252   252   000    Old_age   Always       -       0
  3 Spin_Up_Time            0x0023   085   022   025    Pre-fail  Always   In_the_past 4608
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       -       416
  5 Reallocated_Sector_Ct   0x0033   252   252   010    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x002e   252   252   051    Old_age   Always       -       0
  8 Seek_Time_Performance   0x0024   252   252   015    Old_age   Offline      -       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       -       16591
 10 Spin_Retry_Count        0x0032   252   252   051    Old_age   Always       -       0
 11 Calibration_Retry_Count 0x0032   252   252   000    Old_age   Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       438
181 Program_Fail_Cnt_Total  0x0022   100   100   000    Old_age   Always       -       14823686
191 G-Sense_Error_Rate      0x0022   100   100   000    Old_age   Always       -       19
192 Power-Off_Retract_Count 0x0022   252   252   000    Old_age   Always       -       0
194 Temperature_Celsius     0x0002   064   050   000    Old_age   Always       -       36 (Min/Max 10/50)
195 Hardware_ECC_Recovered  0x003a   100   100   000    Old_age   Always       -       0
196 Reallocated_Event_Count 0x0032   252   252   000    Old_age   Always       -       0
197 Current_Pending_Sector  0x0032   099   094   000    Old_age   Always       -       152
198 Offline_Uncorrectable   0x0030   252   252   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0036   200   200   000    Old_age   Always       -       0
200 Multi_Zone_Error_Rate   0x002a   100   100   000    Old_age   Always       -       1
223 Load_Retry_Count        0x0032   252   252   000    Old_age   Always       -       0
225 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       -       443

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Selective offline   Completed without error       00%     16591         -
# 2  Short offline       Completed without error       00%     16591         -
# 3  Short offline       Completed without error       00%     16318         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0      999  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Completed [00% left] (0-65535)
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root % smartctl  -a /dev/sdb
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-3.18.25-std471-amd64] (local build)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     SAMSUNG SpinPoint F4 EG (AF)
Device Model:     SAMSUNG HD204UI
Serial Number:    S2H7J1CZ917597
LU WWN Device Id: 5 0024e9 00417b426
Firmware Version: 1AQ10001
User Capacity:    2,000,398,934,016 bytes [2.00 TB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    5400 rpm
Form Factor:      3.5 inches
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 6
SATA Version is:  SATA 2.6, 3.0 Gb/s
Local Time is:    Thu Apr 20 23:36:32 2017 UTC

==> WARNING: Using smartmontools or hdparm with this
drive may result in data loss due to a firmware bug.
****** THIS DRIVE MAY OR MAY NOT BE AFFECTED! ******
Buggy and fixed firmware report same version number!
See the following web pages for details:
http://knowledge.seagate.com/articles/en_US/FAQ/223571en
http://www.smartmontools.org/wiki/SamsungF4EGBadBlocks

SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
     was never started.
     Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
     without error or no self-test has ever
     been run.
Total time to complete Offline
data collection:   (20340) seconds.
Offline data collection
capabilities:     (0x5b) SMART execute Offline immediate.
     Auto Offline data collection on/off support.
     Suspend Offline collection upon new
     command.
     Offline surface scan supported.
     Self-test supported.
     No Conveyance Self-test supported.
     Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
     power-saving mode.
     Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
     General Purpose Logging supported.
Short self-test routine
recommended polling time:   (   2) minutes.
Extended self-test routine
recommended polling time:   ( 339) minutes.
SCT capabilities:         (0x003f) SCT Status supported.
     SCT Error Recovery Control supported.
     SCT Feature Control supported.
     SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   100   100   051    Pre-fail  Always       -       0
  2 Throughput_Performance  0x0026   252   252   000    Old_age   Always       -       0
  3 Spin_Up_Time            0x0023   074   067   025    Pre-fail  Always       -       8129
  4 Start_Stop_Count        0x0032   099   099   000    Old_age   Always       -       1703
  5 Reallocated_Sector_Ct   0x0033   252   252   010    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x002e   252   252   051    Old_age   Always       -       0
  8 Seek_Time_Performance   0x0024   252   252   015    Old_age   Offline      -       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       -       8340
 10 Spin_Retry_Count        0x0032   252   252   051    Old_age   Always       -       0
 11 Calibration_Retry_Count 0x0032   100   100   000    Old_age   Always       -       1
 12 Power_Cycle_Count       0x0032   099   099   000    Old_age   Always       -       1945
181 Program_Fail_Cnt_Total  0x0022   100   100   000    Old_age   Always       -       10364821
191 G-Sense_Error_Rate      0x0022   100   100   000    Old_age   Always       -       908
192 Power-Off_Retract_Count 0x0022   252   252   000    Old_age   Always       -       0
194 Temperature_Celsius     0x0002   064   056   000    Old_age   Always       -       35 (Min/Max 16/44)
195 Hardware_ECC_Recovered  0x003a   100   100   000    Old_age   Always       -       0
196 Reallocated_Event_Count 0x0032   252   252   000    Old_age   Always       -       0
197 Current_Pending_Sector  0x0032   252   252   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0030   252   252   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0036   100   100   000    Old_age   Always       -       1
200 Multi_Zone_Error_Rate   0x002a   100   100   000    Old_age   Always       -       5
223 Load_Retry_Count        0x0032   100   100   000    Old_age   Always       -       1
225 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       -       1999

SMART Error Log Version: 1
ATA Error Count: 1
 CR = Command Register [HEX]
 FR = Features Register [HEX]
 SC = Sector Count Register [HEX]
 SN = Sector Number Register [HEX]
 CL = Cylinder Low Register [HEX]
 CH = Cylinder High Register [HEX]
 DH = Device/Head Register [HEX]
 DC = Device Command Register [HEX]
 ER = Error register [HEX]
 ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 1 occurred at disk power-on lifetime: 8288 hours (345 days + 8 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 30 0f 00 00 e0  Error: ABRT at LBA = 0x0000000f = 15

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c5 ff 3f 00 00 00 e0 00      00:00:00.050  WRITE MULTIPLE
  c8 ff 01 00 00 00 e0 00      00:00:00.042  READ DMA
  c8 ff 01 00 00 00 e0 00      00:00:00.042  READ DMA
  c8 ff 01 00 00 00 e0 00      00:00:00.042  READ DMA
  f5 00 00 05 00 00 e0 00      00:00:00.041  SECURITY FREEZE LOCK

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Selective offline   Completed without error       00%      8340         -
# 2  Short offline       Completed without error       00%      8340         -
# 3  Short offline       Completed without error       00%      8312         -
# 4  Short offline       Completed without error       00%      8293         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0      999  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Completed [00% left] (0-65535)
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root %
root@sysresccd /root %


}} ----------------- {{


}} ----------------- {{


}} ----------------- {{


}} ----------------- {{


}} ----------------- {{


}} ----------------- {{


}} ----------------- {{


}} ----------------- {{


}} -----------------
}}

No comments:

Post a Comment