Friday 30 September 2011

varios .. outlook

1and1.es
html5-party - http://globalplaza.org/spaces/html5-party/events/html5-party

fisica física http://www.sc.ehu.es/sbweb/fisica/celeste/forma/forma.htm

--

outlook

reported error (0x800CCC0E) -> Clear SSL State

OAB Download Failed
Event Source: Outlook
Event ID: 27
Event Type: messages, warnings, or information
Description: "OAB Download Failed" appears instead of "OAB Download Succeeded."

--> http://support.microsoft.com/kb/843483/en-us?fr=1


Delete profile: Remove an Outlook e-mail profile
In Microsoft Windows XP
In Control Panel, double-click User Accounts, and then click Mail.
Click Show Profiles.
Select the profile you want to remove, and then click Remove.


Active Sync problem Support Code 85010014
http://answers.microsoft.com/en-us/winphone/forum/wp6n-wptips/active-sync-problem-support-code-85010014/54293da4-3847-4bb8-9574-8a877fcf525f

Avinte 2011-2012

Arevalo 2011.07.16

Visita al campamento arevaloss, donde está el chico. Esta en Arévalo el fin de semana del 16/07/2011

  • Cosas a ver en Arévalo:
  • Románico mudejar en toda la villa - Destaca el castillo del siglo XV con
  • muros de sillería rematados con ladrillos
  • residencia palaciega
  • prisión del estado
  • restaurado en 1950
  • forma pentagonal
  • Rio Adaja y Arevalillo
  • Asados de cordero que llaman tostón
  • Puente mudejar en el Arevalillo, tiene 5 arcadas
  • Al lado de la Plaza Real hay restos de muralla
  • Plaza de la Villa:
  • columnas de madera
  • fuente de 4 caños
  • 2 iglesias mudéjares
  • Monumento al tostón
  • La locomotora de vapor
  • Iglesia de Santa María la Mayor, ver el pantocrator

Vacaciones 2011

Chalet en Cambrils

De segunda mano a través de agencia
29/8 a 12/9 - 15d - 700 e adelantar 30% y fianza 100e pago en efectivo.

Dirección:
Neptu 5, cambrils

Agencia:
Inmobiliaria Teval - www.inmobiliaria-teval.com/
C/ Neptú, 34
43850 Cambrils
977 369 848




--
cxx/xxcxx xx2xx0xx3xx8xx xx9xx5xx xx8xx9xx xx0xx4xx xx6xx0xx0xx0xx1xx6xx9xx6xx7xx2xx
Txxixxtxxuxxlxxaxxrxx xxMxxixxlxxaxxnxxoxx xx3xx0xx0xx0xx xxSxxLxx
Fxxixxnxxcxxaxx xx8xxDxx1xx
--



20 m2 en dos patios anterior y posterior
2 plantas aprox 35 m2 + 20 m2 + terraza de 5 m2
En el bajo: 1 Hab matrimonio, salón, baño con ducha hidromasaje y cocina unida a salón
En la primera planta: 1 Hab matrimonio, y otra 2 literas, un baño minúsculo con ducha y la terraza

A/A -- si pero 8 e/d, no lo cogimos. Dice que es porque hay gente que lo pone a 20º y lo deja puesto todo el día con las ventanas abiertas.
Mantas -- no hacen falta
Toallas y sábanas -- llevar
Piscina en terrena de al lado, compartida entre 4 chalets. Escalera de obra para entrar. tiene aprox 3 x 6 m. va de poco profunda hasta 2m
Cocina:
Olla express -- no
Batidora -- no
Microondas -- si
Lavadora -- si
Lavavajillas -- si
Estaba bien equipada con platos, vasos, sartenes, TV plana
Caja fuerte -- si
Seguridad en la zona, no hay robos. Pero hay que cerrar las puertas. Hay gente que lo deja todo abierto.
Via de tren cercana, no se oye mucho y pasan 1 o 2 trenes por la noche
Playa -- las playas que hay cerca son artificiales con espigones paralelos a la costa. En casi todos los sitios te hundes en unos metros, excepto en la segunda luna al lado del socorrista. Pero como hay que coger le coche es mejor a la del pueblo pasado el puerto y allí tarda muchísimo en cubrir.

Hubo muchísmos mosquitos, y nos picaron un montón. Y eso que pusimos incienso, velas de citronela, de los que se pone en los enchufes que es como ambiertador y nos echamos aután .. no hubo forma nos picaron un montón.

Temperaturas
Piscina 28º
Mar 26.5º
Ambierte de día 29-30
Ambiente de noche 25-26

Zamora visitar y notas

Regenerar catalizador en Renault Scenic de 2006, en realidad es limpiar el FAP (filtro antipartículas):

EGR electrónico
Evaporar gases de escape

Acciones recomendadas por amigo (Oscar) de vecino de cama (Matias) de hospital de Zamora en 2011.02 :
  • Limpiar el catalizador, luego va el FAP
  • Llenar depósito de gasoil con y 1 litro de gasolina
  • Gastarlo 1 vez a bajas vueltas
  • Volver a llenarlo de gasoil con y 1 litro de gasolina
  • Gastarlo completo, esta vez a altas vueltas
  • Anular la EGR
El tema de los coches de segunda mano en los concesionarios está así:
  • Más de 6 años - los venden por lotes a 1.500 euros / vehículo. Luego los venden por 4.000 o 5.000 euros / vehículo.
  • Menos de 6 años - los venden por lotes a 3.000 euros / vehículo. Luego los venden por 6.000 euros / vehículo.
  • Menos de 6 años y muy buen estado, lo venden en el concesionario directamente.

¿ Qué visitar en Zamora desde el Hospital Virgen de la Concha ?

  • Plaza Mayor
  • Ayuntamiento viejo
  • Ayuntamiento nuevo
  • Ir hacia el rio por la Cuesta de Balborraz, se ven casas de oficina y casas antiguas.
  • Bares en la Calle Herreros
  • Plaza de Viriato
  • + Parador Nacional de Condes de Alba de Aliste
  • Palacio de la Diputación
  • Visitar si se puede, tiene arcos y pozao
  • Biblioteca
  • Museo de monedas y cosas antiguas
  • Seguir por la Calle Rúa de los Francos
  • Desde mirador se ve el Puente de Hierro y el Puente de Piedra.
  • Sillón de Doña Urraca
  • Catedral de Zamora, se ve el castillo y la puerta de la traición , y los azudes que cambiaron los romanos. Visitar los molinos de olivares. La catedral tiene tapices y una cúpula bizantina (cimborrio)
  • Cuesta del Obispo, casa del Cid. Calles típicas de la época de caballeros. Son calles en humbría, mejor visitar en verano. Se ve el Puente de Hierro y el Puente de Piedra.

Thursday 22 September 2011

Madrid cursos y talleres

Madrid cursos y talleres en los centros culturales:
  • Plazo - cada año es diferente. Hay que estar atentos, mirar la web o pasar por algún centro que te interese. En la Vaguada el 2010 el plazo de solicitud fue en junio, en 2011 fue del 1 a 7 de septiembre.
  • Solicitud en pdf aquí
  • Pago internet, hay que recoger el abonaré en el Centro Cultural, pagarlo en un banco o por internet y volver a llevarlo al Centro Cultural. Para pago por internet en www.madrid.es buscar: "Pago de impuestos, tasas, distintivos SER, cursos y multas por Internet" o este enlace

Tuesday 13 September 2011

What is RAID?

What is RAID? gracias a hirensbootcd

Thu, Mar 3, 2011


If you are in the computing business where the data security and availability are crucial at all times, chances are you might have already encountered or even worked with RAID. What is RAID? It is not a living thing but it is has become quite popular and seriously vital in many organizations with multiple users across different locations or even home users accessing multiple pictures at a time. RAID is an acronym for Redundant Array of Independent Disks or sometimes referred to as Redundant Array for Inexpensive Disks. The latter has been coined mostly to illustrate capability for generally improving computing performance and data security by using multiple low-cost disks.

In order to get down to the different efficiency pros and cons of various RAID levels, it is more proper to lay down some clarity to many RAID terminologies. Striping is how data are distributed and written into the various disks that will be set up into array either by byte-level or bit-level. Mirroring is the process by which data written into the other disk is copied onto the other disks simultaneously, creating a redundant replica of the other. Parity on the other hand is use alongside with striping and it is computational procedure that allows the array in determining what information has to be stored into what disk.

Standard Levels

Depending on the priority of the user, there are RAID levels that can be set to give more emphasis on some organizational and business decisions crucial to the operation such as increased computing performance, data security, data availability, and data storage capacity.

RAID 0
This array is mostly used by users who pay more for high performance computing. The adage that says “two heads are better than one” holds true for this set-up. It allows but offers no mirroring or redundancy in the process. The increased performance is made possible with the way data are stored and split into several disks in the array. This works wonders for those on the look out for speeding up the read and write computing functionality.

RAID 1
This set-up offers no striping but allows mirroring in the process. As data are identically written on various disks in the array, there is a very slim chance of losing any data even if the other disks fail in the process. However, performance is a little bit compromised compared to RAID0 array as the write process to a single disk may take a bit more time compared to having them split into several disks.

RAID 2
It is implemented by splitting data at the bit level and spreading it over designated data disks and redundancy disks. The redundant bits are calculated using Hamming codes, a form of error correcting code (ECC).

RAID 3
This array is set-up where striping is on a byte-level and with dedicated parity disk. This means that every file is split up amongst the striped drives equally, byte-by-byte, and this is what makes it exceptional because it allows reading of every byte simultaneously across different drives.

RAID 4
This array set-ups a block-level striping and setting aside a disk for dedicated parity). It is similar to RAID 5 except that it confines all parity data to a single disk which can negatively impact on the speed performance. Nonetheless, the error detection is achieved through dedicated parity which is stored in a separate, single disk unit.

RAID 5
This is set-up allows the bit level striping and distributed parity calculation. This is has been the more popular set-up among the earlier set-ups mentioned as it offers the benefits of RAID3 and RAID4 but without the bottleneck experience caused by a dedicated parity computation in a single disk.

RAID 6
This set-up offers the bit-level striping and double distributed parity calculation. This also means more costly on disk arrays as you would have to make available double quantity of the disks. Across the board it offers reasonable performance but slightly lower than what RAID5 allows. It can expensive, too.

Nested (Hybrid) RAID

There are also arrays that employ the combinations of standard RAID levels by attaching both the standard RAID level numbers before and after a “+”, such as 0+1.

RAID 0+1: This refers to striping of data in mirrored sets. Although this has become more complex for ordinary users, this allows fault tolerance and improved performance.

RAID 1+0: This refers to mirroring of data in a striped set.

RAID 5+1: This refers to the set-up with mirrored striped set and with distributed parity.

The above descriptions and set-up explanations are not all the time applicable to low-end users and may not even be comprehensible to some high-end computing professionals. Nevertheless, knowing that there are possible disk solutions to your computing needs is always a useful piece of information.

RAID Test Results vs. Single Drive:

Windows XP error de disco .. durante una operación de paginación

En windows XP el log del sistema (visor de sucesos): error detectado en el dispositivo \Device\Harddisk5\D durante una operación de paginación.


http://www.compartir-tecnologias.es/s/error+detectado+dispositivo/
http://www.compartir-tecnologias.es/error-detectado-el-dispositivo-device-harddisk7-ayuda-200502671.html


En disco laCie de 1T

Tools, enlaces: